Authors: Chaitra K
Abstract: To assess the fire resistance performance of recycled aggregate concrete (RAC) components with varying compressive strengths, four full-scale concrete columns were designed and tested under high-temperature conditions. Two of the specimens were constructed using normal concrete with compressive strengths of C20 and C30, while the other two were made from recycled coarse aggregate (RCA) concrete with compressive strengths of C30 and C40. These specimens were subjected to identical constant axial forces and exposed to simulated building fire conditions in a laboratory furnace. Various parameters from the experimental results were analyzed and compared, including temperature change, vertical displacement, lateral deflection, fire endurance, and failure characteristics. The temperature distribution within the specimens was simulated using ABAQUS Software (ABAQUS Inc., Providence, RI, USA), and the simulated results closely matched the experimental findings. The results indicate that the rate of heat transfer from the surface to the interior of the columns increases with higher concrete compressive strengths for both RAC and normal concrete columns. Under identical initial axial force ratios and column cross-sections, columns with lower concrete compressive strengths exhibited better fire resistance performance. Additionally, the RAC columns demonstrated superior fire resistance performance compared to the normal concrete columns with equivalent compressive strengths.
Keywords: Recycled aggregate concrete (RAC) column; fire resistance; high-temperature test; temperature field; finite element method (FEM) analysis; concrete compressive strength
Full Issue