Vol 1, No 3 (2016)

Reducing the Harmonic Using Dead Time Elimination Scheme for Inverter

Abstract

In order to prevent the power switching devices (e.g., the Insulated-Gate-Bipolar-Transistor, IGBT) from shooting through in voltage source converter during a switching period, a dead- time is inserted in between the off going and turning on devices, either in the hardware drivers of the IGBTs or implemented in the software Sinusoidal Pulse-Width Modulation (SPWM) scheme. Both methods will lead to a degradation of the injected current power quality. This paper will present a dead-time elimination scheme for a SPWM controlled inverter. In comparison to using expensive current sensor, this method determines precisely the load of current polarity by detecting the terminal voltage of the anti-parallel diode of power devices. The presented scheme includes the freewheeling current polarity detection circuit and the PWM control generator without dead-time. This method significantly reduces the output voltage loss and harmonic distortion, and improves quality of power. Simulation results are given to demonstrate the effectiveness of the dead-time elimination scheme.

 

Keywords: Dead time, PWM, Sinusoidal Pulse Width Modulation (SPWM), Harmonics

Full Issue

View or download the full issue PDF

Table of Contents