"Risk Assessment for Seismic Performance and Mitigation Strategies of Transfer Beams in Skyscrapers Incorporating Floating Columns Adopting Computational Analysis"
Abstract
This paper explores the structural behavior of transfer beams in multi-story buildings incorporating floating columns. Utilizing advanced computational tools and design codes (ACI and UBC); a 25-storied building had been modeled to assess the effects of floating columns under different scenarios. Through a combination of theoretical analysis and computational modeling using ETABS, the study explores various parameters, including base shear, bending moments, shear forces, torsion, twisting on transfer beams and deflection analyzing seven different cases where Case 1 and Case 7 were the most economic cases as they were showing 40~50% more economic than other cases as external floating columns are not critical while using same sections of transfer beam. Case 4 instead of Case 5 can be used to introduce shear wall to overcome the lateral loading effect. In Case 6 as less depth of transfer beams had been used than its adequate depth, it showed the highest moment among the cases. Even it had experienced 65% higher shear while using floating column. Both positive and negative shear for transfer beams showed that except Case 1, Case 6-1 and Case 7-1 all the cases experienced greater shear ranging 50~60% which indicated the failure of structure for vertical shear caused by floating column on transfer beam acted as a point load. It was observed that for all cases torsion at ground floor increases, but thereafter floors, there was significant reduction of 75% in torsion occurred and it did not hamper the whole structure as the values of torsion for all cases. Results indicate significant variations in structural stability, with specific configurations showing higher vulnerability. This paper emphasizes the importance of proper design and reinforcement of transfer beams to mitigate risks. The findings provide critical insights for engineers and architects aiming to enhance the safety and performance of high-rise buildings with floating columns.
References
Jawaharlal Puvvala (1996), Analysis and Behavior of Transfer Girder Systems in Tall Building.
Shah B.A., Patodi S.C. (2013), Performance Based Seismic Evaluation of RC Frames with Floating Columns.
Bin Lianga, ZhaoliangZhangb and Rong Li (2013),Optimal Design of SRC Transfer Beam of High-rise Building.
Cu Jianhua, Liu Ping (2013), Structural Stability Analysis of High-Rise Building Transfer Beam High-Formwork Supporting System.
MengzhouLva, Dequan Liu, Xiaoyu Sun (2013), Analysis on Bearing Wall with Opening Transfer Beams Subjected to Vertical Loads.
Bryan Stafford Smith, Alex Coull (2013), Tall building structures: analysis and design
Waykule, Dr.Pise, C.M.Deshmukh, Y.P.Pawar, S.S.Kadam, Mohite, S.VLale (2013), Study of Behavior of Floating Column For Seismic Analysis of Multistoried Building.
Kavya N, Dr. K.Manjunatha, Sachin.P.Dyavappanavar (2013), Seismic Evaluation OfMultistoreyRc Building With And Without Floating Column.
Nikhil Bandwal, AnantPande, VaishaliMendhe, AmrutaYadav (2013), To Study Seismic Behaviour of RC Building with Floating Columns.
PatyushMalaviya (2014), Comparative study of effect of floating column on the cost analysis of a structure designe.
Nakul A. Patil ,Prof. Riyaz Sameer Shah (2014), Comparative Study of Floating and Non-floating Columns With and Without Seismic Behavior.
K.V. Sudheer And Dr. E. Arunakanthi (2014), Design And Analysis of A High-rise Building With and Without Floating Columns.
SreekanthGandlaNanabala, Pradeep Kumar Ramancharla and Arunakanthi (2014), Seismic Analysis of a Normal Building and Floating Column Building.
Susanta Banerjee, Sanjaya Kumar Patro (2014), Estimation of the Park-Ang Damage Index for Floating Column Building with Infill Wall.
AbhayGuleria (2014), Structural Analysis of Multistoried Building using ETABS for different configuration.
IshaRohilla, S.M. Gupta, BabitaSaini (2015), Seismic Response of Multi-Storied Irregular Building With Floating Column.
BadgireUdhav S. Shaikh A.N, Maske Ravi (2015),Analysis Of Multistoried Building With Floating Column.
Prof. SaritaSingla, Er. AshfiRahman (2015), Effect of Floating Columns on Seismic Response of Multi-Storied RC Framed Buildings.
Shiwliroy (2015), Behavioral studies of floating column on framed structure.
NautiyalPrerna, AkhtarSaleem, BathamGeeta (2015),Seismic Response Evaluation of RC frame building with Floating Column considering different Soil Condition.
Fan-shenMeng (2015), Analytical Analysis Of Steel Reinforced Concrete Transfer Beam, IJSRD - International Journal For Scientific Research & Development| Vol. 3, Issue 10, 2015 | ISSN (Online): 2321-0613
Gauav Kumar (2016), Review on seismic analysis of RCC frame structures with floating columns.
Poonam, Anil Kumar and Ashok K. Gupta (2016), Study of Response of Structurally Irregular Building Frames To Seismic Excitations.
AvinashPardhi, Parakh Shah, Satishyadav, PundlikSapat, Amit Kumar Jha (2016), Seismic Analysis Of RCC Building With & Without Floating Columns.
JayashriSarode and Mr. Amol.S. Pote (2016), Analysis Of Floating Column Building Of Composite And R.C.C Beam Girder & Comparison With R.C.C Frame Structure.
ACI CODE-318-11: Building Code Requirements for Structural Concrete and Commentary.
UBC CODE-1997